Enclosed Server Room HFC-227ea Fire Suppression
SANJING FIRE Enclosed server room HFC-227ea fire suppression, automatic HFC-227ea fire extinguishing system is a type of fire suppression system designed to quickly and efficiently extinguish fires in enclosed areas, such as cabinets or server rooms.
SANJING FIRE Enclosed server room HFC-227ea fire suppression, automatic HFC-227ea fire extinguishing system is a type of fire suppression system designed to quickly and efficiently extinguish fires in enclosed areas, such as cabinets or server rooms.
HFC-227ea is a clean agent gas that works by reducing the oxygen levels in the affected area, which extinguishes the fire without causing damage to equipment or leaving behind residue.
In a cabinet automatic HFC-227ea fire extinguishing system, the system is installed directly inside the cabinet or enclosed space, with sensors and detectors that monitor the area for signs of fire. If a fire is detected, the system will automatically activate and release the HFC-227ea gas to suppress the fire.
The HFC-227ea fire extinguishing system has several advantages over other types of fire suppression systems. It is a clean agent that does not leave any residue or damage to the equipment, making it ideal for use in sensitive areas. It also has a high extinguishing efficiency and is able to quickly extinguish fires, reducing the potential for damage or loss of life.
Parameter
|
Cabinet Type FM200 Basic Technical Info’s |
||||||||
|
Model |
GQQ40 |
GQQ70 |
GQQ90 |
GQQ120 |
GQQ150 |
GQQ70X2 |
GQQ90X2 |
GQQ120X2 |
|
Storage Capacity(L) |
40L |
70L |
90L |
120L |
150L |
70LX2 |
90LX2 |
120LX2 |
|
Length(mm) |
500 |
500 |
500 |
500 |
550 |
900 |
900 |
900 |
|
Width(mm) |
500 |
500 |
500 |
500 |
500 |
500 |
500 |
500 |
|
Height(mm) |
1800 |
1750 |
1950 |
2060 |
2000 |
1750 |
1950 |
2060 |
|
Filling Pressure(20℃) |
2.5Mpa |
|||||||
|
Max. Working Pressure(50℃) |
4.2Mpa |
|||||||
|
Filling Density(kg/m³) |
η≤1000 |
|||||||
|
Standard |
GB16670-2006 |
|||||||
|
Head Valve Driver |
Electromagnetic Drive or Electromagnetic/Pneumatic Drive |
|||||||
|
Working Voltage and Current |
DC24V, 1.3A |
|||||||
|
Ambient Temperature |
0℃-50℃ |
|||||||
|
Maximum Single Protected Area |
500㎡ |
|||||||
|
Maximum Single Protected Volume |
1600m³ |
|||||||
|
Discharge Time |
≤10s |
|||||||
|
Start-up Methods |
Automatic Electric, Manual Electric, Manual Mechanical |
|||||||
|
Automatic Start Delay Time |
0-30s Adjustable |
|||||||


Q&A
Q: Do you have the test and audit service?
A: Yes, we can assist to get the designated test report for product and the designated factory audit report.
Q: What’s is your shipping service?
A: We can provide services for vessel booking, goods consolidation, customs declaration, shipping documents preparation and delivery bulk at the shipping port.
Q: Can you provide the FBA shipping service?
A: Yes, we have the good experience in providing the professional FBA service.
Populära Taggar: enclosed server room hfc-227ea fire suppression, China enclosed server room hfc-227ea fire suppression manufacturers, suppliers, factory